1. Horizontal concealed fan coil general description
Horizontal ceiling concealed fan coil units are designed specifically to meet many various requirements demanded for concealed type installation. Commonly used for low static ( free blow or short duct ) application within the closets of motels and apartments.
All fan coil units are completely factory packaged with blower fan, motor, chilled water coil, circuited and terminated pipe connections. Available for following models:
Cooling capacity: 1.8KW to 12.6KW
Heating capacity: 2.7KW to 18.9KW
Air flow: 200 CFM to 1400 CFM
2. Horizontal concealed fan coil unit Applications
(1) Showroom
(2) Shopping mall
(3) Restaurant & Bar
(4) Hotels
(5) Offices
(6) Building
(7) Clean room
(8) Other fields
3. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system) | |||||||||||
Model EST~ | 200HC2 | 300HC2 | 400HC2 | 500HC2 | 600HC2 | 800HC2 | 1000HC2 | 1200HC2 | 1400HC2 | ||
Air flow (m3/h) (0/12Pa,30Pa Static Pressure) | High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium | 270 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | ||
Low | 190 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | ||
Rated cooling capacity | H | TH(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH(W) | 1341 | 2012 | 2682 | 3353 | 4023 | 5364 | 6705 | 8046 | 9387 | ||
M | TH(W) | 1485 | 2187 | 2916 | 3645 | 4374 | 5832 | 7290 | 8748 | 10206 | |
SH(W) | 1152 | 1728 | 2304 | 2880 | 3455 | 4607 | 5759 | 6911 | 8063 | ||
L | TH(W) | 1134 | 1701 | 2268 | 2835 | 3402 | 4536 | 5670 | 6804 | 7938 | |
SH(W) | 930 | 1395 | 1860 | 2325 | 2790 | 3720 | 4649 | 5579 | 6509 | ||
Rated heating capacity | H | W | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 |
M | 2079 | 3119 | 4158 | 5198 | 6237 | 8316 | 10395 | 12474 | 14553 | ||
L | 1634 | 2450 | 3267 | 4084 | 4901 | 6534 | 8168 | 9801 | 11435 |
Horizontal Concealed Fan Coil Unit (4 pipe system) | |||||||||||
Model EST~ | 200HC4 | 300HC4 | 400HC4 | 500HC4 | 600HC4 | 800HC4 | 1000HC4 | 1200HC4 | 1400HC4 | ||
Air flow (m3/h) (0/12Pa,30Pa Static Pressure) | High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium | 270 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | ||
Low | 190 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | ||
Rated cooling capacity | H | TH(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH(W) | 1341 | 2012 | 2682 | 3353 | 4023 | 5364 | 6705 | 8046 | 9387 | ||
M | TH(W) | 1485 | 2187 | 2916 | 3645 | 4374 | 5832 | 7290 | 8748 | 10206 | |
SH(W) | 1152 | 1728 | 2304 | 2880 | 3455 | 4607 | 5759 | 6911 | 8063 | ||
L | TH(W) | 1134 | 1701 | 2268 | 2835 | 3402 | 4536 | 5670 | 6804 | 7938 | |
SH(W) | 930 | 1395 | 1860 | 2325 | 2790 | 3720 | 4649 | 5579 | 6509 | ||
Rated heating capacity | H | W | 1080 | 1620 | 2160 | 2700 | 3240 | 4320 | 5400 | 6480 | 7560 |
M | 832 | 1248 | 1663 | 2079 | 2495 | 3326 | 4158 | 4990 | 5821 | ||
L | 654 | 980 | 1307 | 1634 | 1960 | 2614 | 3267 | 3920 | 4574 |
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
Ceiling concealed fan coil unit
Ceiling exposed fan coil unit
(1)The Proof of Quality:
Now we have customers in different countries and places, such as Mexico, Australia, New Zealand, Singapore, Argentina, Ukraine, Uzbekistan, Middle- East, Africa…
(2)The Guarantee of Quality: Reasonable design, Professional technicians, Stable production workers, Full-scale Equipments, Strict QA & QC system…
(3)Custom ade Design:
We supply our design drawing according to customer practical situation.
(4) Technique Support:
We supply our wiring diagram, installation instructions and maintenance manual, make more easier for installation.
(5) International Trade Operation:
We have concentrated on international trade of fan coil units for many years, accumulated various experience from different customers of different countries. So we can update our operation in time according to our customers and new rules. It is helpful to clear customs and save cost and time for our customers.
6. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
7.FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
9. Ceiling concealed fan coil installation instruction
10. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..